In-line integrity (high voltage) testing
Testing the integrity of aseptic process packaging is a regulatory requirement, requiring all units to be inspected. The objective of this test is to ensure that there is no microhole in the packaging, which would allow the entry/exit of gases, enabling the contamination of the product and/or reduction of its shelf life. Applicable to aqueous products, the high voltage technology applies an electric caraga to the packaging and through the analysis of the behavior of this electric charge it is possible to identify microholes in the packaging, imperceptible to the human eye. The test is non-destructive, that is, it does not damage the packages and the equipment delivers speeds of up to 36,000 units per hour.